Sign In | Join Free | My burrillandco.com
Home > Battery Testing Equipment >

15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer from wholesalers
     
    Buy cheap 15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer from wholesalers
    • Buy cheap 15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer from wholesalers
    • Buy cheap 15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer from wholesalers

    15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SNBT4004FA-30V10A, SNBT4008FA-15V10A,
    Certification : Calibration Certificate (Cost Additional)
    Price : Customized
    Payment Terms : T/T, L/C, Western Union, MoneyGram
    Supply Ability : 10 Sets Per Month
    Delivery Time : 1 Month
    • Product Details
    • Company Profile

    15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

    15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer

    Overview:

    This sieries of battery and cell charge discharge testing equipment meets the requirements of lithium ion battery or lead acid battery pulse charge and discharge test, DC internal resistance (DCIR) test, cycle life (Cycle Life) test, rate charge and discharge test. This testing equipment comes with unique software, which can run on computer to achieve romote control and minitor.
    This series of battery testing systems are widely used in various research institutions, universities and power battery manufacturers.

    Technical Parameters:

    Project index

    Parameter index

    Input PowerAC 220V±10%/50Hz (or can be customized)
    ResolutionAD:16bit; DA:16bit
    Input Resistance≥1MΩ
    Input Power

    1722W (for 15V model)
    1620W (for 30V model)

    Channel Control FeatureConstant current source and constant voltage source adopt independent double closed loop structure
    Channel Control ModeIndependent control
    VoltageVoltage Range Per Channel

    75mV-15V (for 15V model)
    0.15V-30V (for 30V model)

    Minimum discharge voltage0V
    Accuracy± 0.1% of FS
    Stability± 0.1% of FS
    CurrentCurrent Range Per Channel50mA~10A
    Constant voltage cutoff current20mA
    Accuracy± 0.1% of FS
    Stability± 0.1% of FS
    PowerOutput Power Per Channel

    150W (for 15V model)
    300W (for 30V model)

    Stability± 0.2% of FS
    TimeCurrent Response TimeTime of current rising to 10A is 20ms
    Step Time Range1s~365*24 hour, Time Form Support 00: 00: 00:000(h, min, s, ms)
    Data RecordingRecord ConditionTime△t: 100ms

    Voltage△U:30mV (for 15V model)
    Voltage△U:60mV (for 30V model)

    Current△I: 20mA
    Record Frequency10Hz
    ChargeCharge ModeConstant current charging, constant voltage charging, constant current and constant voltage charging, constant power charging, constant current and constant voltage of the battery pack
    Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
    DischargeDischarge ModeConstant current discharge, constant power discharge, constant resistance discharge
    Cutoff ConditionVoltage, Current, Relative Time, Capacity, -ΔV
    Pulse ModeCharge modeConstant current mode, Constant power mode
    Discharge modeConstant current mode, Constant power mode
    Min. pulse width500ms
    Number of pulseSingle pulse step supports 32 different pulses
    Continuous switching of charge and dischargeA pulsed step can achieve continuous switching from charge to discharge
    Cutoff conditionVoltage, relative time
    DCIR TestSupports custom point retrieval for DCR calculations
    CycleLoop Measure Range1~65535 times
    Max Steps Per Loop254
    Nested LoopWith nested loop function, max support 3 layers
    ProtectionSoftware Protection
    • Power-down Data Protection
    • Off-line Testing Function
    • Setting Protection Condition, Setting Parameter: Low Voltage limit, Upper Voltage limit, Low Current limit, Upper Current limit, Delay Time
    Voltage and current detection samplingFour-wire connection
    Noise<85dB
    DatabaseMySQL Database
    A Means of Communication of Upper MachineTCP/IP Protocol
    Data OutputEXCEL2003,2010,TXT
    Communication InterfaceEthernet Port
    Main Channels No. Per Unit

    8 (for 15V model)
    4 (for 30V model)

    Leakage Current

    0.015mA (for 15V model)
    0.03mA (for 15V model)

    Dimensions12U chamber, W*D*H: 600 *600*740(mm)
    FixtureTo be determined


    Equipment Working Environment :

    Project index

    Parameter index

    Working Temperature Range10℃ ~ 40℃1
    Storage Temperature Range-10℃ ~ 50℃
    Working Environment Relative Humidity Range≤70% RH (No condensation)
    Storage Environment Relative Humidity Range≤80% RH (No condensation)
    Auxiliary channel voltage range (optional and customized)-5V~5V

    Auxiliary channel voltage accuracy
    (optional and customized)

    ±0.1%ofFS

    The number of channels, voltage range, current range and etc. can be customized according client's specific requirements and specimen. Please email or call to Sinuo for further assistance.




















    Quality 15V/10A 30V/10A Primary Dry Batteries Capacity Test Equipment Charge Discharge Analyzer for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)