Sign In | Join Free | My burrillandco.com
Home > Energy Efficiency Lab >

Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

Sinuo Testing Equipment Co. , Limited
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers
     
    Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers
    • Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers
    • Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers
    • Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers
    • Buy cheap Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test from wholesalers

    Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

    Ask Lasest Price
    Brand Name : Sinuo
    Model Number : SN331
    Certification : Calibration Certificate (Cost Additional)
    Price : Tailored
    Payment Terms : T/T
    Supply Ability : 1 Set Per Month
    Delivery Time : 2 Months
    • Product Details
    • Company Profile

    Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test


    3HP Air Enthalpy Method Calorimeter Testing Laboratory for Air Conditioners and Heat Pumps


    Overview:


    The test laboratory can accurately measure the air conditioning cooling capacity, heating capacity, cooling power consumption, heating power consumption, EER, COP, and inverter air conditioner’s rated / maximum / intermediate / minimum cooling capacity, rated / low temperature / intermediate / heating, cooling and heating power consumption, EER, COP, SEER and APF, etc.


    The test laboratory can test 1~3PH household air conditioners. The test models cover all types of window, split wall mount, split cabinet and split ceiling cassette.


    The test laboratory uses the air enthalpy method to measure the amount of cooling and heating capacity generated by the measured unit. The laboratory is divided into indoor and outdoor rooms. The indoor room mainly simulates the indoor working condition environment, and the outdoor room mainly simulates the outdoor working condition environment. The outdoor side temperature can be as low as -10 ° C and up to 50 ° C. Can meet the performance testing requirements of household air conditioning.


    Standards:


    Design and Testing according to the following standards:

    ► ISO 5151:2010

    ► ISO 16358:2013

    ► Other standards can be customized


    Types of UUT :


    - Split wall type

    - Split cabinet type

    - Split ceiling cassette type

    - Window type

    - Inverter air conditioner


    Testing Range:


    Test range

    Cooling capacity

    (W)

    Heating capacity

    (W)

    Input power

    (W)

    Air Flow

    (m³/h)

    ≤7500≤9000≤8000200~2000

    Indoor Size Dry bulb TemperatureIndoor Size Wet bulb TemperatureOutdoor Size Dry bulb TemperatureOutdoor Size Wet bulb TemperaturePower
    Control Range0~50℃0~50℃-10~55℃0~55℃(Relative humidity control below 0°C,0~95%RH)0~8KW
    Control Accuracy±0.2±0.2±0.2±0.2±0.5%
    Display Accuracy±0.1±0.1±0.1±0.1±0.1%

    Technical Indicators:


    Working conditionsIndoor side air return condition of /℃Outdoor side air inlet condition of /℃
    Dry bulb temperatureWet bulb temperatureDry bulb temperatureWet bulb temperature
    Cooling operationRated coolingT127193524
    T221152719
    T329194624
    Maximum coolingT132234326
    T227193524
    T332235231
    Freeze-upT1211521-
    T210-
    T321-
    Minimum cooling2115Minimum temperature recommended by the manufacturer

    Condensation

    Condensate removal

    27242724
    Heating operationHeat pump rated heatingHigh temperature2015(Max.)76
    Low temperature21
    Extra-low temperature-7-8
    Maximum heating operation27-2418
    Minimum heating operation20--5-6
    Automatic defrost201221
    Electric heating rated heating20---

    System flowchart:


    Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

    Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test

    Quality Air Conditioners / Heat Pumps Energy Efficiency Lab 3HP Air Enthalpy Method Calorimeter Test for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Sinuo Testing Equipment Co. , Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)